Magnetizing power sources are intended for magnetizing the material by direct passing of AC or DC (HWDC or FWDC) in magnetic particle non-destructive testing and, in case of DUO (dual) power sources, for simultaneous magnetizing by the coil as well. Power sources may be turned on separately or simultaneously.

Standard delivery for all models

  • independent control and measurement of current
  • output switching on is done manually
  • control of current is performed by thyristor controller
  • demagnetization is performed automatically whenever the current is switched off
  • source is also equipped with a 230 V / 10 A socket for connecting the UV lamp

MT Magnetizing Power Sources

Optional accessories (for extra charge):

  • cables
  • footswitch pedal
  • magnetizing prods with replaceable zinc tips
  • pulse magnetizing with adjustable pulse duration
  • pneumatic clamping control for serial testing
  • control of nozzle activation for serial testing
  • touch panel for complete control of source with automatic settings of parameters according to the product under test
  • tatistics of achieved currents and magnetization times

 

Modifications are possible according to the customer's requirements and wishes.
ZP   600 1000 1000H 1500 1500H 2000 2000H 2500 2500H 3000 3000H 4000 4000H 5000 5000H
max. testing current (with power cables)
AC effective  (true RMS) A 600 1000 1000 1500 1500 2000 2000 2500 2500 3000 3000 4000 4000 5000 5000
AC peak value A 852 1420 1420 2130 2130 2840 2840 3550 3550 4260 4260 5680 5680 7100 7100
HWDC effective A 600 - 750 - 1000 - 1300 - 2500 - 3000 - 4000 - 5000
HWDC peak value A 852 - 1500 - 2000 - 2600 - 2500 - 4000 - 6000 - 8000
open circuit voltage A 4 4,5 5 5 5 6 5 6 6 7 7 8 8 9
AC demagnetizing   available available available available available available available available
operating parameters:
type (portable, mobile, stationary)   P P M M M,S M,S M,S M,S M,S M,S M,S M,S M,S M,S M,S M,S
power supply V 320 230 400 400 3x400 3x400 3x400 3x400 3x400 3x400
socket A 16 16 32 32 32 32 32 32 63 63 125 125 125 125 125 125
cunsumption at operating current kVA 2,6 3,5 5,7 6,9 7,8 10 12 13 18 28 41
current measuring accuracy % ±10 ±10 ±10 ±10 ±10 ±10 ±10 ±10
load capacity % 35 35 35 35 35 35 35 35
recommended connecting cable (not included) m 2,5 2,5 2x2,5 2x2,5 2x2,5 2x3,0 2x3,0 2x4,0 2x4,0
cable cross section mm² 95 95 95 2x70 2x95 2x95 2x120 4x95 4x120
dimensions cm 20x22x44 48x66x77 48x66x77 48x66x77 48x66x77 68x66x77 68x66x77 68x66x77
weigth of the basic version (DUO+30) kg 17 20 50 60 60 70 70 80 80 90 110 120 130 140 150 160
protection IP   40 40 20 20 20 20 20 20 20 20

 