English (United Kingdom)

Coating thickness gauges CM-88xx Print
Monday, 29 January 2007 17:41
Coating thickness gauges CM-88xxCoating thickness gauges CM-88xx series are lowcost entry level gauges for industrial users who need instant and easy to use measurements.



Thickness coating gauge CM-8820 F

  • Type of probe (F) ferromagnetic base material
  • Operating principle: magnetic induction
  • Measuring range: 0-2000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±5%n or ±5um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AA battery
  • Auto power off
  • Operating conditions:0-+45℃,≤90%RH
  • Dimensions: 160x68x32mm
  • weight: 210g (not including battery)
  • Calibration block and foils
  • Plastic transport case

Coating thickness gauges CM-88xx



Thickness coating gauge CM-8821 F

  • Type of probe (F) ferromagnetic base material
  • Operating principle: magnetic induction
  • Measuring range: 0-1000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±1-3%n nebo ±2,5um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AA battery
  • Auto power off
  • Operating conditions:0-+45℃,≤90%RH
  • Dimensions: 160x68x32mm
  • weight: 210g (not including battery)
  • Calibration block and foils
  • Plastic transport case

     
Coating thickness gauges CM-88xx


Thickness coating gauge CM-8822 F/FN

  • Type of probe (F) ferromagnetic base material and (NF) nonferromagnetic base
  • Operating principle: magnetic induction and Eddy current
  • Measuring range: 0-1000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±1-3%n nebo ±2,5um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AA battery
  • Auto power off
  • Operating conditions:0-+45℃,≤90%RH
  • Dimensions: 160x68x32mm
  • weight: 210g (not including battery)
  • Calibration block and foils
  • Plastic transport case


Coating thickness gauges CM-88xx



Thickness coating gauge CM-8823 FN

  • Type of probe (F) ferromagnetic base material and (NF) nonferromagnetic base
  • Operating principle: magnetic induction and Eddy current
  • Measuring range: 0-1000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±1-3%n nebo ±2 um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AA battery
  • Auto power off
  • Dimensions: 160x68x32mm
  • Operating conditions:0-+45℃,≤90%RH
  • weight: 210g (not including battery)
  • Calibration block and foils
  • Plastic transport case



Coating thickness gauges CM-88xx


Thickness coating gauge CM-8825 F/NF built in dual probe


  • Type of probe (F) ferromagnetic base material and (NF) nonferromagnetic base
  • Operating principle: magnetic induction and Eddy current
  • Measuring range: 0-1000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±1-3%n nebo ±2,5um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AAA battery
  • Auto power off
  • Dimensions: 126x65x27mm
  • Operating conditions:0-+45℃,≤90%RH
  • weight: 81g (not including battery)
  • Calibration block and foils
  • Plastic transport case

Coating thickness gauges CM-88xx



Thickness coating gauge CM-8826 F/NF

  • Type of probe (F) ferromagnetic base material and (NF) nonferromagnetic base
  • Operating principle: magnetic induction and Eddy current
  • Measuring range: 0-1000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±1-3%n nebo ±2,5um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AAA battery
  • Auto power off
  • Dimensions: 126x65x27mm
  • Operating conditions:0-+45℃,≤90%RH
  • weight: 81g (not including battery)
  • Calibration block and foils
  • Plastic transport case

Coating thickness gauges CM-88xx


Thickness coating gauge CM-8828 F/NF built in dual probe

  • Type of probe (F) ferromagnetic base material and (NF) nonferromagnetic base
  • Operating principle: magnetic induction and Eddy current
  • Measuring range: 0-1000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±1-3%n nebo ±2,5um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AAA battery
  • Auto power off
  • Dimensions: 126x65x27mm
  • Operating conditions:0-+45℃,≤90%RH
  • weight: 81g (not including battery)
  • Calibration block and foils
  • Plastic transport case


Coating thickness gauges CM-88xx




Thickness coating gauge CM-8829 F/NF


  • Type of probe (F) ferromagnetic base material and (NF) nonferromagnetic base
  • Operating principle: magnetic induction and Eddy current
  • Measuring range: 0-1000 um
  • Resolution; 0.1 (99.9um)/ 1 (100 um+)
  • Accuracy: ±1-3%n nebo ±2,5um
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Battery indicator: low battery indicator
  • Power supply: 4x1.5V AAA battery
  • Auto power off
  • Dimensions: 126x65x27mm
  • Operating conditions:0-+45℃,≤90%RH
  • weight: 81g (not including battery)
  • Calibration block and foils
  • Plastic transport case


  •  
Coating thickness gauges CM-88xx


 
© 2010 PTS Josef Solnar - Full Service NDT Company
Joomla! is Free Software released under the GNU General Public License.