Digital magnetometers MH series are intended for measurement of magnetic field intensity or residual magnetic field by means of external Hall sensor included in set. Units of measure are kA/m or gauss (it’s depend on model).The device is lightweight and compact, reliable and easy to work and can be used both in laboratory measurements and in industry or field conditions.
- Contrast LCD – display allows you to use the device in conditions with different light. MH series magnetometers allow you to choose the device with necessary limit of measurement.
- MH series magnetometers are seriate produced by our firm. In agreement with the customer it’s possible to make specialized measurers taking into account the individual conditions of use (for example with a built-in Hall sensor for easy use in the operations of conveyor production).
Magnetometer MH 04 – residual magnetic field intensity gauge
- Range: 0-19,99 kA/m, 199,9 Gauss
- Exceeding upper limit of measurement indicator
- Polarity field indicator
- Accuracy: 2% of the last value of measurement range
- Tangential Hall sensor with 1m cable without connector
- Power supply: battery 4,8 V 750 mAh (4xAAA)
- Power consumption: up to 20 mА
- Low battery indicator
- Charging time : a. 5 hours
- Size: 75mm x120mm x30mm
- Weight: 160 g
- Supply in valise with charger
- Supply with a certificate of calibration

Magnetometer MH 05 – intensity magnetic field gauge
-
Range: ±, 0 - 1,99 kA/m, 0 - 19,9 gauss ±, 0 - 19,9 kA/m, 0 - 199,9 gauss ±, 0 - 49,9 kA/m, 0 - 499,9 gauss
-
Measured magnetic fields: AC and DC with indication of a polarity
-
Tangential Hall sensor with 1m cable without connector
-
Power supply: battery 6 V 750 mAh (5xAAA)
-
Accuracy: ± 5 % of measured value + 2 dig. ± 2 %. of last value of range + 2 dig.
-
Charging time: a. 5 hours, automatic control
-
Temperature range: 0-50oC
-
Supply in valise with charger
-
Supply with a certificate of calibration

Magnetometer MH 06 – intensity magnetic field gauge
- Range: ±, 0 - 1,99 kA/m, 0 - 19,9 gauss
- Resolution: 0,001 kА/m or 0,01 gauss
- Measured magnetic field: DC with polarity indication
- Exceeding upper limit of measurement indicator
- Tangential Hall sensor with 0,8m cable with connector
- Accuracy: ± 5 % of measured value + 5 dig.
± 2 % of last value of range + 5 dig.
- Power supply: 2 alkaline batteries AAA 1,5 V
- Low battery indicator: measurement is blocked when battery’s discharged, “-1” is indicated on the display
- Power consumption: 24 mA (typical)
- Temperature range: 0-50oC
- Size: 62mm x110mm x27mm
- Weight: 200 g with sensor and battery

Magnetometer MH 07- intensity magnetic field gauge
- Range: ±, 0 – 19,9 kA/m, 0 - 199 gauss
- Resolution: 0,01 kА/m or 0,1 gauss
- Measured magnetic field: DC with polarity indication
- Exceeding upper limit of measurement indicator
- Tangential Hall sensor with 0,8m cable with connector
- Accuracy: ± 5 % of measured value + 5 dig.
± 2 % of last value of range + 5 dig.
- Power supply: 2 alkaline batteries AAA 1,5 V
- Low battery indicator: measurement is blocked when battery’s discharged, “-1” is indicated on the display
- Power consumption: 24 mA (typical)
- Temperature range: 0-50oC
- Size: 62mm x110mm x27mm
- Weight: 200 g with sensor and battery

|